Environmental testing for operators and contractors.
Laboratory data for environmental and social impact assessments, discharge monitoring, spill investigations and remediation sign-off, to the standard expected by international operators and lenders.
Water
Drinking, ground, surface and wastewater analysis for monitoring programmes and permits.
| Parameter | Instrument | Typical reference |
|---|---|---|
| Heavy metals and trace elementsCompares water quality with drinking-water and discharge standards. | Agilent 7700 Series ICP-MS | EPA 200.8 |
| MercuryOne of the most strictly regulated contaminants in water, measured at very low levels. | Analytik Jena mercur | |
| TOC and total nitrogenA general indicator of organic pollution and nutrient load in water. | Analytik Jena multi N/C 3100 | EN 1484 |
| VOCs and BTEXDetects fuel and solvent contamination, for example from leaking tanks or pipelines. | Agilent 7697A Headspace SamplerAgilent 5977A MSD | EPA 8260 |
| Pesticides and herbicidesChecks agricultural run-off and drinking-water sources against regulatory limits. | Agilent 7000C Triple Quadrupole GC/MSAgilent 6130 Quadrupole LC/MS |
Soil, sediment & waste
Contamination assessment for baseline, spill and remediation studies.
| Parameter | Instrument | Typical reference |
|---|---|---|
| Metals and mercuryEstablishes contamination levels before construction and after operations. | Agilent 7700 Series ICP-MSAnalytik Jena mercur | |
| Petroleum hydrocarbonsMeasures oil contamination in soil, the key parameter for spill assessment and clean-up sign-off. | Agilent 7890B GC System | |
| PAHs and semi-volatile organicsDetects toxic, long-lasting compounds from oil, combustion and industrial residues. | Agilent 5977A MSD | EPA 8270D |
| Persistent organic pollutantsIdentifies legacy pollutants such as PCBs and old pesticides that require special handling. | Agilent 7000C Triple Quadrupole GC/MS | |
| MineralogyDescribes the natural composition of soil and sediment: the baseline against which change is measured. | Bruker D2 PHASER XRD |
Investigations
When the question is “what is this, and where did it come from?”.
| Parameter | Instrument | Typical reference |
|---|---|---|
| Non-target screening of unknown contaminantsFinds and identifies unexpected contaminants when you don’t know what you are looking for. | Agilent 6550 iFunnel Q-TOF LC/MS | |
| Source fingerprinting of hydrocarbon spillsMatches spilled oil to its source, supporting incident investigations and liability questions. | Agilent 5977A MSD | |
| Particle and residue identificationIdentifies unknown particles, films and residues found on equipment, in products or in samples. | JEOL JSM-7500F FE-SEMAgilent Cary 630 FTIR |
References indicate typical standard methods. The exact method, detection limit and turnaround are confirmed in each quotation. Parameters not listed may also be available.
Not sure which test you need?
Describe the problem, such as corrosion, an off-spec batch, a discharge permit or an export requirement, and our analysts will recommend the right tests.
Other industries

Oil & gas
Gas composition, sulfur, mercury, metals, fuels, lubricants, produced water and failure analysis for upstream and downstream operations.
Learn more
Fertilizers
Nitrogen, nutrients, heavy-metal contaminants, phase composition and thermal stability for nitrogen, phosphate and potash producers.
Learn moreSend us your parameter list
Tell us the sample type and the parameters you need, or send a product specification. We reply with the applicable methods and a quotation.
Request a quote